C3.3 | DE65E0

DE65E0 (50 Hz) Generator Set

DE65E0 (50 Hz) 65 kVA Diesel Generator Set

DE65E0 Open Rear Right

DESCRIPTION

Producing reliable power 65 kVA at 60 Hz, our DE65E0 generator set powerd by C3.3 diesel engine designed to ISO 8528-5 transient response requirements.Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.Electric Power

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

M-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

Fully prototype tested with certified torsional vibration analysis available

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

  • Control panel
    • GCCP Control panel
  • Alternator and Alternator attachments
    • 12 Leads
    • IP23 Protection
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 Pole, mounted in tower panel
  • Governing system
    • Mechanical governor
  • Cooling system
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Air inlet system
    • Air cleaner; light duty with disposable element
  • Exhaust system
    • Stub pipe, gaskets, raincap & SAE exhaust flange
    • Industrial silencer
  • Fuel system
    • Standard open set fuel tank/base
  • Lube system
    • Lubricating oil
    • Oil drain line with valve
  • Mounting system
    • Captive linear vibration isolators
    • Lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
  • Starting/charging system
    • 12V Battery with rack & cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Control panel
    • GCCP Control panel
    • Earth fault and earth leakage
    • Emergency E-Stop with security key
    • 4 Pole Circuit breaker
    • Voltage and speed adjust potentiometer
  • Alternator and Alternator Attachments
    • LC Frame alternator
    • LC/M Frame alternator
    • Space heater
    • Permanent magnet excitation (PMG)
    • Automatic voltage regulator
  • Enclosures
    • Level 1 and Level 2 sound attenuated enclosures
    • Single point lifting frame
    • Rental pack
    • SBOX - CEE form sockets
  • Alarms and Shutdowns
    • Common alarm
    • Overload shutdown
    • Low coolant level shutdown
    • Low coolant temperature alarm
    • Low fuel level alarm and shutdown
    • High fuel level alarm
  • Engine
    • Electronic governor
    • Jacket water heater
    • Battery charger
  • Fuel system
    • Bunded base tank sized for a minimum of 12 hours running with 110% spill protection
  • Exhaust system
    • Residential silencer 25 dBA
  • Certification
    • Certificate of Conformance
    • EAC Certification
  • Extended service coverage
    • 3, 4, 5 and 10 Years

Specs

Overview

Long Name:
DE65E0 (50 Hz) Generator Set
Name:
C3.3 | DE65E0
Brand:
Cat
Status:
Current

Generator Set Specifications

Minimum Rating
65 kVA
Maximum Rating
65 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
Cat® C3.3
Bore
4.1 in / 105 mm
Stroke
5 in / 127 mm
Displacement
201.4 in³ / 3.3 l
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
75.8 in / 1925 mm
Width - Maximum
44.1 in / 1120 mm
Height - Maximum
53.6 in / 1361 mm
Dry Weight - Genset (maximum)
1926 lb / 874 kg

SEE HOW C3.3 | DE65E0 COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets
C3.3 | DE65E0
DE65E0 Open Rear Right
Brand
Cat
Status
Current
Minimum Rating
65 kVA
Maximum Rating
65 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Model
Cat® C3.3
Bore
4.1 in / 105 mm
Stroke
5 in / 127 mm
Displacement
201.4 in³ / 3.3 l
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical
Length - Maximum
75.8 in / 1925 mm
Width - Maximum
44.1 in / 1120 mm
Height - Maximum
53.6 in / 1361 mm
Dry Weight - Genset (maximum)
1926 lb / 874 kg
Diesel Generator Sets
C3.3 | DE56AE0
DE56AE0
Brand
Cat
Status
Current
Minimum Rating
40 ekW
Maximum Rating
45 ekW
Emissions/Fuel Strategy
Non-Certified Emissions
Voltage
220 to 380 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
Engine Model
Cat® C3.3
Bore
4.1 in / 105 mm
Stroke
5 in / 127 mm
Displacement
201.4 in³ / 3.3 l
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical
Length - Maximum
66.1 in / 1680 mm
Width - Maximum
760 mm / 29.9 in
Height - Maximum
52.5 in / 1333 mm
Dry Weight - Genset (maximum)
1795 lb / 814 kg
Diesel Generator Sets
C3.3 | DE75AE0
DE75AE0
Brand
Cat
Status
Current
Minimum Rating
60.0 kVA
Maximum Rating
75.0 kVA
Emissions/Fuel Strategy
Non-Certified Emissions
Voltage
220 to 380 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Model
Cat® C3.3
Bore
4.1 in / 105 mm
Stroke
5 in / 127 mm
Displacement
201.4 in³ / 3.3 l
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical
Length - Maximum
66.1 in / 1680 mm
Width - Maximum
760 mm / 29.9 in
Height - Maximum
52.5 in / 1333 mm
Dry Weight - Genset (maximum)
1788 lb / 811 kg