DE1250S GC

DE1250S GC

DE1250S GC (60 Hz) 1250 ekW Diesel Generator

DE1250S GC

DESCRIPTION

Producing reliable power at 1250 ekW, 60 Hz, our DE1250S GC diesel generator set is made to meet your needs in standby applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. This generator set offers a low fuel consumption system.1250 ekW Generator Set for Standby applicationsElectric Power

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

DE1100 GC
DE1100 GC

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR500 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

DE1100 GC
DE1100 GC

GCCP1.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

DE1100 GC
DE1100 GC

Certifications

  • Low Fuel Consumption

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

DE1100 GC
  • Standard Equipment
  • Optional Equipment
  • Specs
  • Docs

Standard Equipment

Optional Equipment

  • Control Panels
    • Remote monitoring software
  • Starting/Charging
    • Jacket water heater
  • General
    • Single element or dual element air cleaner
    • Circuit breaker panel, based on regional and product configuration

Specs

Overview

Long Name:
DE1250S GC
Name:
DE1250S GC
Brand:
Cat
Status:
Current

Generator Set Specifications

Minimum Rating
1250 eKW
Maximum Rating
1250 eKW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 - 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.71 in / 145 mm
Stroke
6.38 in / 162 mm
Displacement
1958.86 in³ / 32.1 l
Compression Ratio
15.0:1
Aspiration
TA
Fuel System
EUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Minimum
164.3 in / 4175 mm
Length - Maximum
164.3 in / 4175 mm
Width - Minimum
82.3 in / 2090.5 mm
Width - Maximum
82.3 in / 2090.5 mm
Height - Minimum
89.3 in / 2268 mm
Height - Maximum
89.3 in / 2268 mm
Dry Weight - Genset (minimum)
15606 lb / 7079 kg
Dry Weight - Genset (maximum)
15606 lb / 7079 kg

SEE HOW DE1250S GC COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets
DE1250S GC
DE1250S GC
Brand
Cat
Status
Current
Minimum Rating
1250 eKW
Maximum Rating
1250 eKW
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
380 - 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.71 in / 145 mm
Stroke
6.38 in / 162 mm
Displacement
1958.86 in³ / 32.1 l
Compression Ratio
15.0:1
Aspiration
TA
Fuel System
EUI
Governor Type
Adem™A4
Length - Minimum
164.3 in / 4175 mm
Length - Maximum
164.3 in / 4175 mm
Width - Minimum
82.3 in / 2090.5 mm
Width - Maximum
82.3 in / 2090.5 mm
Height - Minimum
89.3 in / 2268 mm
Height - Maximum
89.3 in / 2268 mm
Dry Weight - Genset (minimum)
15606 lb / 7079 kg
Dry Weight - Genset (maximum)
15606 lb / 7079 kg
Diesel Generator Sets
DE1250 GC
DE1250 GC
Brand
Cat
Status
Current
Minimum Rating
1250 kVA
Maximum Rating
1250 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
400 - 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.71 in / 145 mm
Stroke
6.38 in / 162 mm
Displacement
1958.86 in³ / 32.1 l
Compression Ratio
15.0:1
Aspiration
TA
Fuel System
EUI
Governor Type
Adem™A4
Length - Minimum
164.3 in / 4175 mm
Length - Maximum
164.3 in / 4175 mm
Width - Minimum
73.1 in / 1856 mm
Width - Maximum
73.1 in / 1856 mm
Height - Minimum
87.3 in / 2217.5 mm
Height - Maximum
87.3 in / 2217.5 mm
Dry Weight - Genset (minimum)
15606 lb / 7079 kg
Dry Weight - Genset (maximum)
15606 lb / 7079 kg
Diesel Generator Sets
DE1400 GC
DE1400 GC
Brand
Cat
Status
Current
Minimum Rating
1400 kVA
Maximum Rating
1400 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
400 - 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.71 in / 145 mm
Stroke
6.38 in / 162 mm
Displacement
1958.86 in³ / 32.1 l
Compression Ratio
14.0:1
Aspiration
TA
Fuel System
EUI
Governor Type
Adem™A4
Length - Minimum
164.3 in / 4175 mm
Length - Maximum
164.3 in / 4175 mm
Width - Minimum
82.3 in / 1856 mm
Width - Maximum
82.3 in / 1856 mm
Height - Minimum
89.3 in / 2268 mm
Height - Maximum
89.3 in / 2268 mm
Dry Weight - Genset (minimum)
16393 lb / 7436 kg
Dry Weight - Genset (maximum)
16393 lb / 7436 kg